Getting Started

The material in this chapter covers the installation, configuration and invocation of ART 3.0.

Installing ART

ART is included in the standard Scream! distribution for Windows, which is available for free download.

ART uses the Matlab runtime library for its mathematical routines. This is supplied as part of the installer and may be freely distributed.

To download Scream!, send an e-mail to scream@guralp.com, including information about your institution and the type(s) of equipment you are using.

To install the package, double-click on its icon and follow the instructions in the installer. Choose the Typical installation option to ensure that ART and its supporting libraries are all installed.

Setting up sensor information

Before it can analyse data from your instruments, ART needs to know detailed calibration information for each one.

Note: If you start ART from within Scream! (as in section 2.3.2 on page 11) without setting up the relevant sensor information, you will receive an error message saying:

A VPC= entry for {SYSTEM_ID-SERIAL} was not found in calvals.txt

and you should follow the procedure in this section before re-trying.

The calibration information must be provided in a file called calvals.txt, which should be kept in the ART/Scream! program directory. You can create and edit this file from inside Scream! by right-clicking on the digitizer's icon in the main window and selecting Calvals....

The file is divided into sections, each beginning with a title in square brackets. The title gives the System ID and serial number (as given by the first four characters of the Stream ID) for the digitizer which produces the data stream.

For example: to add calibration information for a digitizer with System ID GURALP outputting streams DEMOZ2, DEMON2, DEMOE2, etc., you would add a section beginning with the line

[GURALP-DEMO]

If you move an instrument from one digitizer to another, you will need to update the calvals.txt file to reflect the change.

Sensor

Sensor type code

(response-type)

Units

(V/A)

CMG-5T or 5TD,

DC – 100 Hz response

CMG-5_100HZ

A

CMG-40T-1 or 6T-1,

1 s – 100 Hz response

CMG-40_1S_100HZ

V

CMG-40T-1 or 6T-1,

2 s – 100 Hz response

CMG-40_2S_100HZ

V

CMG-40T-1 or 6T-1,

10 s – 100 Hz response

CMG-40_10S_100HZ

V

CMG-40, 20 s – 50 Hz response

CMG-40_20S_50HZ

V

CMG-40, 30 s – 50 Hz response

CMG-40_30S_50HZ

V

CMG-3T or 3ESP,

30 s – 50 Hz response

CMG-3_30S_50HZ

V

CMG-40, 60 s – 50 Hz response

CMG-40_60S_50HZ

V

CMG-3T or 3ESP,

60 s – 50 Hz response

CMG-3_60S_50HZ

V

CMG-3T or 3ESP,

100 s – 50 Hz response

CMG-3_100S_50HZ

V

CMG-3T or 3ESP,

120 s – 50 Hz response

CMG-3_120S_50HZ

V

CMG-3T, 360 s – 50 Hz response

CMG-3_360S_50HZ

V

CMG-3TB or 3V / 3ESP borehole, 30 s – 50 Hz response

CMG-3B_30S_50HZ

V

CMG-3TB or 3V / 3ESP borehole, 100 s – 50 Hz response

CMG-3B_100S_50HZ

V

CMG-3TB or 3V / 3ESP borehole, 120 s – 50 Hz response

CMG-3B_120S_50HZ

V

CMG-3TB or 3V / 3ESP borehole, 360 s – 50 Hz response

CMG-3B_360S_50HZ

V

CMG-3TB or 3V / 3ESP borehole, 360 s – 50 Hz response

CMG-3B_360S_100HZ

V

Examples

The calibration information for a CMG-3T weak-motion velocity sensor might look like the following:

[GURALP-CMG3]

Serial-Nos=T3X99

VPC=3.153,3.147,3.159

G=1010,1007,1002

COILCONST=0.02575,0.01778,0.01774

CALVPC=3.161

CALRES=51000

TYPE=CMG-3T

RESPONSE=CMG-3_30S_50HZ V

GRAVITY=9.80122

CMG-5TD accelerometers use 1 Ω calibration resistors, and their coil constant is set to unity. Older CMG-5TD instruments, based on Mk2 digitizer hardware, do not have calibration input facilities, and thus the CALVPC entry is omitted. For example:

[GURALP-CMG5]

Serial-Nos=T5585

VPC=2.013,2.028,2.036

G=0.256,0.255,0.255

COILCONST=1,1,1

CALRES=1

TYPE=CMG-5T

RESPONSE=CMG-5_100HZ A

GRAVITY=9.81089

Starting ART

ART can be started in two ways, either from SCREAM or by double clicking on the ART icon.

Start from the ART icon

Double-clicking on the ART icon will start the application and cause the main ART window to open.

Clicking on the ‘Import data’ button at the top of the left-hand column of the main ART window opens up a file selection window from which a GCF time-history can be selected to import and analyze.

Starting from SCREAM

Within Scream!, open a WaveView window displaying the event you are interested in. Click on the Pause icon to stop the traces moving then, using the mouse, select the parts of the time-histories that you want to analyze while holding down either the Ctrl or Shift keys.

If you use the Ctrl key, the first and last streams in the selected area will be analyzed. This is useful for picking two streams from many for comparison. If you use the Shift key, a contiguous set of streams are selected.

When the Ctrl or Shift key is released, a pop-up menu will appear (after a short delay) asking which add-on program you want to run. Select ART and the main ART window will open with the selected time-histories automatically loaded.

The picture below shows a Scream! WaveView window with two streams selected (using the Shift key).



The second illustration shows the selection of two non-adjacent streams for comparison, using the Ctrl key