Outputs and response

Low gain output options

g,g, 1 g, 0.5 g, 0.1 g

Corresponding high gain outputs

0.4g , 0.2 g, 0.1 g, 0.05 g, 0.01 g

Clip level at 4 g

4.2 g

Peak output

±10 V differential

Nominal output impedance

47 Ω

Dynamic range, 0.005 – 0.05 Hz

> 145 dB

Dynamic range, 3 – 30 Hz

> 127 dB

Standard frequency band

DC > 100 Hz
(–3 dB point)

Optional low-pass corner

50, 100 or 200 Hz

Linearity

0.1 % of full scale

Cross-axis rejection

0.001 g / g

Calibration controls

Open-loop response

Connector pin

External inputs

Sine-wave, step, or pseudo-random

Physical

Lowest spurious resonance

> 450 Hz

Operating temperature range

–20 to +70 °C

Pressure jacket material

Hard anodised aluminium

Power / signal connector

Mil-spec connector on sensor housing (KPT02A16-26P)

Weight

1310 g

Power

Current at 12 V DC

51 mA

Current at 12 V DC
(3-way power option)

2 × 12 mA (nominal)