Breve Ocean Bottom Seismometer System
Chapter 11. Appendix 3: Detailed Specifications
Seismometer | |
Configuration/topology | Triaxial orthogonal |
Output bandwidth | 10 seconds to 100 Hz |
Output sensitivity | 5 V/m/s2 |
Clip level | 0.1g |
Lowest spurious resonance | > 300 Hz |
Hydrophone | |
Model | HTI-96-Min |
Output bandwidth | 2 Hz – 30 kHz |
Output sensitivity | -165 dB rel 1 V/ μPa (562 V/bar) |
Battery | |
Battery type | Lithium-ion polymer |
Maximum deployment time | 6 months |
Digitiser | |
Type | Guralp CD24 |
Primary inputs | Four (3 x seismometer; 1 x hydrophone) |
Digital resolution / output format | 24-bit |
ADC type | Sigma-delta |
Sample rates available | User-selectable up to 1000 sps |
Data storage capacity | 60 GB |
Environmental | |
Maximum deployment depth | 100 m (rope deployment); 2000 m (ROV) |
Operating temperature range | 1 °C to +40 °C (tested) |